GAE Series

GAE Series

25 Amp Rating

  • 14 x 7.2(1 POLE)/15.4(2 POLES) x 13.5(H) mm.
  • 25A Max Switching Capacity.
  • Tiny Size with Various Contact Forms.
  • Suitable for Light and Motor Control in Automotive.
  • UL Class H Insulation Available.
SKU: GAE Tag:
Clear

Description

CONTACT RATINGS
Contact Form 1A, 1C, 2A, 2C
Contact Res. ≤100mΩ
Contact Material Ag Alloy (AgSnO2, AgNi)
Rated Load FORM A FORM C
NO NC
25A 16VDC 25A 16VDC 15A 16VDC
Max. Current 25A 15A
Max. Power 400W 240W
Max. Voltage 16VDC
Min. Load 1A at 6VDC


COIL DATA
STANDARD Approx. 640mW (800mW on Request)
Rated Voltage (VDC) Operate Voltage (VDC) Release Voltage (VDC) Max. Voltage (VDC) Nominal Current (mA) Coil Res. (Ω)±10%
5 ≤3 ≥0.5 8.3 128 39
12 ≤7.2 ≥1.2 19.9 53.3 225
24 ≤14.4 ≥2.4 39.8 26.67 900



Additional information

Weight 4 g
Dimensions 14 × 7.2 × 13.5 mm
Max. Capacity

25A 16VDC

Contact Form

1 Form A, 1 Form C, 2 Form A, 2 Form C

Operate Time

≤10ms

Release Time

≤10ms

Insulation Resistance

100MΩ (@500VDC)

Dielectric Strength (I/O)

500VAC 1min

Dielectric Strength (O/O)

500VAC 1min

Shock Resistance

Non-energized: 10G; Destructiion: 100G; Malfunction: 10G

Vibration Resistance

Destruction: 10 to 55Hz (Double Amplitude); Malfunction: 10 to 55Hz (Double Amplitude)

Ambient Temperature

Operating: -40℃ – 125℃

Ambient Humidity

Operating: 5% – 85%

Mount Type

PCB Pin (DIP/TH)

Color

Black

Model Number Legend
GAE S 1 C / 24VDC
(1) (2) (3) (4)
(1) Seal Type: Nil: Flux Proofed; X: Sealed Type.
(2) NO of Pole: 1: Single Pole; 2: Double Pole.
(3) Contact Form: A: Form A / Normally Open; C: Form C / Change Over.
(4) Coil Voltage: X / XX VDC: DC Coil Voltage Value.



Major Model Ordering Chart
Enclosure Rating Contact Form Coil Power Model Coil Voltage
Sealed Type SPST 0.64W GAE-S1A 5VDC
12VDC
24VDC
SPDT GAE-S1C
DPST GAE-S2A
DPDT GAE-S2C




When ordering, add rated coil voltage to model.

Example: GAE-S1C /24VDC





PRECAUTIONS REGARDING COIL INPUT

For the operation of AC relays, the power source is almost always a commercial frequency (50 or 60 Hz) with standard voltages of 6, 12, 24, 48, 120, 230 and 240VAC. Due to this, when the voltage is ohter than the standard voltage, the product becomes special model.

PRECAUTIONS REGARDING CONTACT

For the operation of AC relays, the power source is almost always a commercial frequency (50 or 60 Hz) with standard voltages of 6, 12, 24, 48, 120, 230 and 240VAC. Due to this, when the voltage is ohter than the standard voltage, the product becomes special model.

PRECAUTIONS REGARDING SOLDERING CONDITION

We recommend wave solder, the recommended temperature is 240°C 464°F to 260°C 500°F, and the time is 2s to 5s, time should no longer than 2s when temperature reach 250°C 500°F or above.