GCA Series

GCA Series

Amp Rating

  • 12.5 x 7.5 x 10(H) mm.
  • 2A Max Switching Capacity.
  • 3rd Gen Telecom, High Sensitive Coil, Only 0.2W.
  • Excellent for Communication Devices.
SKU: GCA Tags: , ,
Clear

Description

CONTACT RATINGS
Contact Form 1C
Contact Res. ≤100mΩ
Contact Material Ag Alloy (AgSnO2, Gold Plated)
Rated Load FORM C
2A 125VAC
2A 30VDC
Max. Current 2A
Max. Power 250VA/60W
Max. Voltage 125VAC/30VDC
Min. Load 10mA at 5VDC


COIL DATA
STANDARD Approx. 200mW
Rated Voltage (VDC) Operate Voltage (VDC) Release Voltage (VDC) Max. Voltage (VDC) Nominal Current (mA) Coil Res. (Ω)±10%
3 ≤2.25 ≥0.3 6 66.7 45
5 ≤3.75 ≥0.5 10 40 125
6 ≤4.5 ≥0.6 12 33.3 180
9 ≤6.75 ≥0.9 18 22.2 405
12 ≤9 ≥1.2 24 16.67 720
18 ≤13.5 ≥1.5 30 11.1 1,620
24 ≤18 ≥2.4 48 8.3 2,880



Additional information

Weight 2.3 g
Dimensions 12.5 × 7.5 × 10 mm
Max. Capacity

2A 125VAC/30VDC

Contact Form

1 Form C

Operate Time

≤7ms

Release Time

≤5ms

Insulation Resistance

1,000MΩ (@500VDC)

Dielectric Strength (I/O)

1,000VAC 1min

Dielectric Strength (O/O)

400VAC 1min

Shock Resistance

Non-energized: 10G; Destructiion: 100G; Malfunction: 10G

Vibration Resistance

Destruction: 10 to 55Hz (Double Amplitude); Malfunction: 10 to 55Hz (Double Amplitude)

Ambient Temperature

Operating: -40℃ – 85℃

Ambient Humidity

Operating: 5% – 85%

Mount Type

PCB Pin (DIP/TH)

Color

Black

Model Number Legend
GCA 1 C X / 24VDC
(1) (2) (3) (4)
(1) NO of Pole: 1: Simple Pole.
(2) Contact Form: C: Form C / Change Over.
(3) Customer Code: X: Customer Code, not Related to Construction.
(4) Coil Voltage: X / XX VDC: DC Coil Voltage Value.



Major Model Ordering Chart
Contact Form Coil Power Model Coil Voltage
SPDT 0.2W GCA-1C 3VDC
5VDC
6VDC
9VDC
12VDC
18VDC
24VDC




When ordering, add rated coil voltage to model.

Example: GCA-1C /24VDC





PRECAUTIONS REGARDING COIL INPUT

For the operation of AC relays, the power source is almost always a commercial frequency (50 or 60 Hz) with standard voltages of 6, 12, 24, 48, 120, 230 and 240VAC. Due to this, when the voltage is ohter than the standard voltage, the product becomes special model.

PRECAUTIONS REGARDING CONTACT

For the operation of AC relays, the power source is almost always a commercial frequency (50 or 60 Hz) with standard voltages of 6, 12, 24, 48, 120, 230 and 240VAC. Due to this, when the voltage is ohter than the standard voltage, the product becomes special model.

PRECAUTIONS REGARDING SOLDERING CONDITION

We recommend wave solder, the recommended temperature is 240°C 464°F to 260°C 500°F, and the time is 2s to 5s, time should no longer than 2s when temperature reach 250°C 500°F or above.

You've just added this product to the cart: