CONTACT RATINGS | |||
---|---|---|---|
Contact Form | 1A, 1B, 1C | ||
Contact Res. | ≤50mΩ | ||
Contact Material | Ag Alloy (AgSnO2, AgSnO2In2O3, AgCdO) | ||
Rated Load | FORM A | FORM C | |
NO | NC | ||
50A 240VAC (H Type) 50A 28VDC (H Type) 40A 240VAC 40A 28VDC |
50A 240VAC (H Type) 50A 28VDC (H Type) 40A 240VAC 40A 28VDC |
35A 240VAC (H Type) 35A 28VDC (H Type) 30A 240VAC 30A 28VDC |
|
Max. Current | 50A | 35A | |
Max. Power | 12,000VA/1,400W | 1,250VA/980W | |
Max. Voltage | 240VAC/28VDC | ||
Min. Load | 500mA at 5VDC |
COIL DATA | |||||
---|---|---|---|---|---|
DC Coil | Approx. 900mW | ||||
Rated Voltage (VDC) | Operate Voltage (VDC) | Release Voltage (VDC) | Max. Voltage (VDC) | Nominal Current (mA) | Coil Res. (Ω)±10% |
5 | ≤3.75 | ≥0.5 | 6.5 | 180 | 27.8 |
6 | ≤4.5 | ≥0.6 | 7.8 | 150 | 40 |
9 | ≤6.75 | ≥0.9 | 11.7 | 100 | 90 |
12 | ≤9 | ≥1.2 | 15.6 | 75 | 160 |
18 | ≤13.5 | ≥1.8 | 23.4 | 50 | 360 |
24 | ≤18 | ≥2.4 | 31.2 | 37.5 | 640 |
48 | ≤36 | ≥4.8 | 62.4 | 18.75 | 2,560 |
110 | ≤82.5 | ≥11 | 143 | 8.18 | 13,444.4 |
AC Coil | Approx. 2VA | ||||
Rated Voltage (VDC) | Operate Voltage (VDC) | Release Voltage (VDC) | Max. Voltage (VDC) | Nominal Current (mA) | Coil Res. (Ω)±10% |
24 | ≤19.2 | ≥4.8 | 31.2 | 83.33 | 100 |
120 | ≤96 | ≥24 | 156 | 16.67 | 2,500 |
220 | ≤176 | ≥44 | 286 | 9.09 | 13,490 |
Additional information
Weight | 35 g |
---|---|
Dimensions | 32.2 × 27 × 19.3 mm |
Certified Approval | cULus, TUV |
Max. Capacity | 40A 240VAC/28VDC, 50A 240VAC/28VDC |
Contact Form | 1 Form A, 1 Form B, 1 Form C |
Operate Time | ≤15ms |
Release Time | ≤10ms |
Coil Power | 0.9W, 2VA |
Insulation Resistance | 100MΩ (@500VDC) |
Dielectric Strength (I/O) | 4,500VAC 1min |
Dielectric Strength (O/O) | 1,500VAC 1min |
Impluse Withstand Voltage | 6kV (1.2 x 50μs) |
Shock Resistance | Non-energized: 10G; Destructiion: 100G; Malfunction: 10G |
Vibration Resistance | Destruction: 10 to 55Hz (Double Amplitude); Malfunction: 10 to 55Hz (Double Amplitude) |
Ambient Temperature | Operating: -40℃ – 105℃ |
Ambient Humidity | Operating: 5% – 85% |
Mount Type | PCB Pin (DIP/TH) |
Color | Black, White |
Model Number Legend | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GPA | – | S | 1 | A | D | H | – | K | F | 6 | 24VDC | |||
(1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | ||||||
(1) | Enclosure Rating: | Nil: Flux Proof; S: Plastic Sealed. | ||||||||||||
(2) | NO of Pole: | 1: Single Pole. | ||||||||||||
(3) | Contact Form: | A: Form A / Normally Open; B: Form B / Normally Closed; C: Form C / Change Over. | ||||||||||||
(4) | Contact Material: | Nil: Silver Alloy (ROHS Complaint); D: Ag Alloy (Other Materials). | ||||||||||||
(5)* | Contact Capacity: | Nil: Standard Capacity (up to 40Amp); H: High Capacity (up to 50Amp). | ||||||||||||
(6)* | Coil Power: | Nil: Standard Coil Power: 0.9W for DC, 2VA for AC; K: High Coil Power: 1.2W for DC, 1.6W for 50A; | ||||||||||||
(7)* | Insulation Class: | Nil: Standard Insulation – Class B; F: Insulation – Class F. | ||||||||||||
(8)* | The 6th Pin: | Nil: No 6th Pin; 6: With 6th Pin. | ||||||||||||
(9) | Coil Voltage: | X / XX / XXX VDC or VAC: Coil Voltage Value. | ||||||||||||
*: Shown as suffix, not show in model number. |
Major Model Ordering Chart | ||||||
---|---|---|---|---|---|---|
Enclosure Rating | Contact Form | Capacity | Coil Power | Insulation | Model | Coil Voltage |
Flux Proof | SPST | NO: 40A | 2VA | Class B | GPA-1A | 24VAC 120VAC 220VAC |
0.9W | 5VDC 6VDC 9VDC 12VDC 18VDC 24VDC 48VDC 110VDC |
|||||
SPDT | NO: 40A NC: 30A |
GPA-1C | 5VDC 12VDC 24VDC 48VDC 110VDC |
For high power type, we suggest to select flux proof version for better heat distribution if the relay will not exposed in high humidity/sulphide/dust environment.
For standard type, materials used already meet Class B insulation requirements.
When ordering, add rated coil voltage to model.
PRECAUTIONS REGARDING COIL INPUT
For the operation of AC relays, the power source is almost always a commercial frequency (50 or 60 Hz) with standard voltages of 6, 12, 24, 48, 120, 230 and 240VAC. Due to this, when the voltage is ohter than the standard voltage, the product becomes special model.
PRECAUTIONS REGARDING CONTACT
For the operation of AC relays, the power source is almost always a commercial frequency (50 or 60 Hz) with standard voltages of 6, 12, 24, 48, 120, 230 and 240VAC. Due to this, when the voltage is ohter than the standard voltage, the product becomes special model.
PRECAUTIONS REGARDING SOLDERING CONDITION
We recommend wave solder, the recommended temperature is 240°C 464°F to 260°C 500°F, and the time is 2s to 5s, time should no longer than 2s when temperature reach 250°C 500°F or above.