JMU (MOS) Series

Featured

JMU (MOS) Series

AmpAmp Rating

  • 6.8 x 4.3 x 2(H) mm.
  • Perfect for AC Load, Support up to 2A.
  • Highly Sensitive, No EMI/RFI Generation.
  • No Moving Parts, High Reliability.
  • Arc-free With No Snubbing Circuit, Low On-Resistance.
  • Low Drive Power Requirement, Tiny Size.
Clear

Description

RATINGS
Contact Form 1 FORM A
ITEM SYMBOL CONDITION JMU40 JMU60 JMU80-R JMU4H REMARKS
OUTPUT Load Voltage VL 40V (AC Peak or DC) 60V (AC Peak or DC) 80V (AC Peak or DC) 400V (AC Peak or DC)
Load Current (Continuous) IL 2A (AC/DC) 500mA (AC/DC) 1.25A (AC/DC) 120mA (AC/DC)
Peak Load Current ILPEAK 1ms; 1 shot; VL=DC 5A 2A 3A 600mA
Power Dissipation POUT 350mW 300mW 350mW 300mW
INPUT LED Forward Current IF 50mA
Peak Forward Current IFPEAK f=100Hz; Duty +0.1% 500mA 1A
LED Reverse Voltage VR 5V
Power Dissipation PIN 75mW
Total Dissipation PT 400mW 350mW 400mW 350mW





Please refer to datasheet for more characteristics.

Additional information

Weight 0.4 g
Dimensions 6.8 × 4.3 × 2 mm
Load Voltage

400V, 40V, 60V, 80V

Max. Capacity

0.12A 220VAC/14VDC, 0.5A 220VAC/14VDC, 1.25A 220VAC/14VDC, 2A 220VAC/14VDC

Contact Form

1 Form A

Operate Time

≤3ms

Release Time

≤0.5ms

Insulation Resistance

1,000MΩ (@500VDC), 10,000MΩ (@500VDC)

Dielectric Strength (I/O)

1,500VAC 1min, 3,750VAC 1min

Shock Resistance

Non-energized: 10G; Destructiion: 100G; Malfunction: 10G

Vibration Resistance

Destruction: 10 to 55Hz (Double Amplitude); Malfunction: 10 to 55Hz (Double Amplitude)

Ambient Temperature

Operating: -30℃ – 85℃

Ambient Humidity

Operating: 5% – 85%

Mount Type

SOP

Color

Black

Model Number Legend
JMU 4H 1 R L S 4
(1) (2) (3) (4) (5) (6)
(1) Load Voltage: 4H: 400V.
(2) Contact Form: 1: 1 Form A (AC/DC).
(3) Type: Nil: Standard; R: Low On-resistance Type.
(4) Isolation Grade: Nil: Standard 3750Vrms; L: Economic 1500Vrms.
(5) Package Type: S: SOP.
(6) Pin Numbers: Pin Numbers: number stands for pin numbers



Major Model Ordering Chart
Load Voltage Contact Form Type Isolation Grade Package Type Model
40V 1 FORM A Standard Standard SOP 4 JMU401S4
Economic JMU401LS4
60V Standard Standard JMU601S4
Economic JMU601LS4
80V Standard Standard JMU801S4
Economic JMU801LS4
Low On-resistance Standard JMU801RS4
400V Standard Standard JMU4H1S4
Economic JMU4H1LS4




SOP package has reel packaging, when ordering, add R to end of the model.

Example: JMU4H1LS4 R





PRECAUTIONS REGARDING COIL INPUT

For the operation of AC relays, the power source is almost always a commercial frequency (50 or 60 Hz) with standard voltages of 6, 12, 24, 48, 120, 230 and 240VAC. Due to this, when the voltage is ohter than the standard voltage, the product becomes special model.

PRECAUTIONS REGARDING CONTACT

For the operation of AC relays, the power source is almost always a commercial frequency (50 or 60 Hz) with standard voltages of 6, 12, 24, 48, 120, 230 and 240VAC. Due to this, when the voltage is ohter than the standard voltage, the product becomes special model.

PRECAUTIONS REGARDING SOLDERING CONDITION

We recommend wave solder, the recommended temperature is 240°C 464°F to 260°C 500°F, and the time is 2s to 5s, time should no longer than 2s when temperature reach 250°C 500°F or above.