Featured

GME Series

16 Amp20 Amp Rating

  • 23 x 16.2 x 10.2(H) mm.
  • 20A Max Switching Capacity, Suits Complex Load.
  • Sensitive Coil, Meets Energy Saving Application.
  • Class F Insulation and Glow Wire Version Available.
  • Certified with    
Clear

Description

CONTACT RATINGS
Contact Form 1A
Contact Res. ≤100mΩ
Contact Material Ag Alloy (AgSnO2, AgSnO2In2O3)
Rated Load FORM A
20A 277VAC (H Type)
16A 250VAC
Max. Current 20A
Max. Power 5,540VA
Max. Voltage 277VAC
Min. Load 100mA at 5VDC


COIL DATA
STANDARD Approx. 200mW
Rated Voltage (VDC) Operate Voltage (VDC) Release Voltage (VDC) Max. Voltage (VDC) Nominal Current (mA) Coil Res. (Ω)±10%
5 ≤4 ≥0.5 6.5 40 125
6 ≤4.8 ≥0.6 7.8 33.3 180
9 ≤7.2 ≥0.9 11.7 22.2 405
12 ≤9.6 ≥1.2 15.6 16.67 720
18 ≤14.4 ≥1.8 23.4 11.1 1,620
24 ≤19.2 ≥2.4 31.2 8.3 2,880
48 ≤38.4 ≥4.8 62.4 4.7 11,520



Additional information

Weight 9 g
Dimensions 23 × 16.2 × 10.2 mm
Certified Approval

CQC, cULus, TUV

Max. Capacity

16A 250VAC, 20A 277VAC

Contact Form

1 Form A

Operate Time

≤15ms

Release Time

≤5ms

Coil Power

0.2W

Insulation Resistance

1,000MΩ (@500VDC)

Dielectric Strength (I/O)

2,500VAC 1min

Dielectric Strength (O/O)

1,000VAC 1min

Shock Resistance

Non-energized: 10G; Destructiion: 100G; Malfunction: 10G

Vibration Resistance

Destruction: 10 to 55Hz (Double Amplitude); Malfunction: 10 to 55Hz (Double Amplitude)

Ambient Temperature

Operating: -40℃ – 125℃

Ambient Humidity

Operating: 5% – 85%

Mount Type

PCB Pin (DIP/TH)

Color

Black

Model Number Legend
GME S 1 A D H F XXX / 24VDC
(1) (2) (3) (4) (5) (6) (7) (8)
(1) Enclosure Rating: Nil: Flux Proof; S: Plastic Sealed.
(2) NO of Pole: 1: Single Pole.
(3) Contact Form: A: Form A / Normally Open.
(4) Contact Material: Nil: Silver Alloy (ROHS Complaint); D: Ag Alloy (Other Materials).
(5) Contact Capacity: Nil: Standard Capacity (up to 16Amp); H: High Capacity (up to 20Amp).
(6) Insulation Class: Nil: Standard Insulation – Class B; F: UL Insulation – Class F.
(7) Customer Code: XXX: Customer Code, not Related to Construction.
(8) Coil Voltage: X / XX VDC: DC Coil Voltage Value.



Major Model Ordering Chart
Enclosure Rating Contact Form Capacity Coil Power Insulation Model Coil Voltage
Flux Proof SPST NO: 20A 0.2W Class B GME-S1A 5VDC
6VDC
9VDC
12VDC
18VDC
24VDC
48VDC
Plastic Sealed NO: 16A GME-1A(H)




For high power type, we suggest to select flux proof version for better heat distribution if the relay will not exposed in high humidity/sulphide/dust environment.
For standard type, materials used already meet Class F insulation requirements.
When ordering, add rated coil voltage to model.

Example: GME-S1A /12VDC





PRECAUTIONS REGARDING COIL INPUT

For the operation of AC relays, the power source is almost always a commercial frequency (50 or 60 Hz) with standard voltages of 6, 12, 24, 48, 120, 230 and 240VAC. Due to this, when the voltage is ohter than the standard voltage, the product becomes special model.

PRECAUTIONS REGARDING CONTACT

For the operation of AC relays, the power source is almost always a commercial frequency (50 or 60 Hz) with standard voltages of 6, 12, 24, 48, 120, 230 and 240VAC. Due to this, when the voltage is ohter than the standard voltage, the product becomes special model.

PRECAUTIONS REGARDING SOLDERING CONDITION

We recommend wave solder, the recommended temperature is 240°C 464°F to 260°C 500°F, and the time is 2s to 5s, time should no longer than 2s when temperature reach 250°C 500°F or above.

You've just added this product to the cart: